|
| - ibaPDA
The modern classic of data acquisition - ibaHD-Server
Historical data immediately available - ibaQDR
Length-based recording of quality data - ibaQPanel
Displaying quality data - live and in color - ibaInSpectra
Real-time monitoring of process vibrations
|
| | - ibaAnalyzer
Powerful analyzing and evaluating of measured data - ibaAnalyzer-InSpectra
Detailed offline vibration analysis - ibaAnalyzer-Reportgenerator
Automatic generation of individual reports - ibaDatCoordinator
Data management automation - ibaAnalyzer-DB
The database interface for ibaAnalyzer
|
| | - ibaBM-CAN
Bus monitor for CAN/CANopen - ibaBM-DP
Bus monitor for PROFIBUS - ibaBM-eCAT
Bus monitor for EtherCAT® - ibaBM-ENetIP
Bus monitor for EtherNet/IP - ibaBM-PN
Bus monitor for PROFINET - ibaBM-DDCS
Bus monitor for DDCS drive buses
|
| | - ibaCapture
Measure, view and understand - ibaVision
Industrial image processing in real time
|
| | - ibaPADU-8AI-U/ibaPADU-8AI-I
Analog/digital input modules for data acquisition up to 1 kHz - ibaPADU-D-8AI-U/ibaPADU-D-8AI-I
Analog/digital input modules for data acquisition up to 40 kHz - ibaPADU-4-AI-U
Analog/digital input module for fast sampling up to 100 kHz - ibaPADU-C
Analog/digital data logger for grid independent measurements
|
| | - Condition Monitoring
- Reducing plant downtimes, avoiding false alarms
- Real Time Vibration Monitoring
- Online monitoring: Optimizing processes, increasing product quality
- Offline Vibration Analysis
- Detailed analysis, parameterization and configuration
|
| | - Local Data Acquisition with Connection to Cloud Services and Databases
|
| | |
| | |
| | - Powerful industrial PCs, PC connections, FO infrastructure
|
| | - Measurement and Automation in one System
|
| | - Measurement and Automation in one System
|
| | Intelligent Central Units and I/O Modules with suitable Interfaces
|
| | - ibaBM-ENetIP
- Acquire data via EtherNet/IP
- ibaPDA-Interface-EtherNet/IP
- Acquire data via Ethernet
- ibaPDA-Interface-Logix-Xplorer
- Connection via Xplorer interface
|
| | Interfaces to various PLC systems
|
| | - ibaBM-DP
- Acquire data via PROFIBUS
- ibaBM-PN
- Acquire data via PROFINET
- ibaPDA-Interface-S7-TCP/UDP
- Acquire data via Ethernet
- ibaPDA-Interface-S7-Xplorer
- Connection via Xplorer interface
|
| | - ibaBM-DP
- Acquire data via PROFIBUS
- ibaBM-PN
- Acquire data via PROFINET
- ibaPDA-Interface-Profinet-CP
- Acquire data via PROFINET
- ibaPDA-Interface-SIMOTION-Xplorer
- ibaPDA-Interface-SINAMICS-Xplorer
- Connection via Xplorer interface
|
| | - ibaBM-eCAT
- Acquire data via EtherCAT
- EtherCAT diagnostics
- ibaPDA-Interface-Generic-TCP
- ibaPDA-Interface-Generic-UDP
- Acquire data via Ethernet
- ibaPDA-Request-TwinCAT
- Acquire data using the Request method
- ibaPDA-Interface-TwinCAT-Xplorer
- Connection via Xplorer interface
|
| | - ibaPQU-S
- Modular Power Quality Monitoring System
- ibaNet750-BM-D
- Power measurement with WAGO power terminals
- ibaPDA-Interface-IEC61850
- Integration of IEC 61850 compatible protection devices
|
| | - ibaPDA-PLC-Xplorer
- Measuring from the beginning
- ibaAnalyzer
- Powerful analyzing and evaluating of measured data
|
| | - ibaW-750
- Central unit for WAGO I/O system 750 with Ethernet connection
- ibaNet750-BM-D
- Central unit for WAGO I/O system 750 with fiber optic connection
|
| | - ibaHD-Server
Historical data available immediately
|
| | Acquire and analyze signals synchronously and precisely |
| | |
| | |
Flyers |
| | |
| | - 3D-views of geometric objects, machines or plants
- Animation of objects with ibaLogic and ibaPDA-V6 measuring values, simulation and control data
- Interactivity via virtual control panel
- Processing of current or recorded data
- Interfaces to OPC and iba measuring files
- Import of standard 3D engineering data (dxf, stl)
- 40 behavioral parameters can be configured for each object
- Events can be viewed at the same time at different locations
- Improved analysis due to linking with ibaAnalyzer
- 10 Objects are free of charge
- Can be operated intuitively and is cost-effective
|
| | - Synchronized recording of video capture and measured data with ibaPDA-V6
- Continuous and event-triggered recording
- Storage protection for important recordings
- Up to 16 analog and/or IP cameras
- Replay and analysis of video recordings synchronously with measured data in ibaAnalyzer
- Easy configuration with ibaPDA-V6 I/O manager
- Live view of video capture for up to 16 cameras
|
| | - High speed video capture with ibaCapture-CAM
- Supports GigE Vision® compliant cameras
- Up to 4 GigE cameras per Server
- Resolution levels up to HD quality
- Continuous and event-triggered recording
- Supports image processing applications with ibaCapture-CAM Machine Vision interface add-on1)
|
| | - Synchronized recording of HMI screen activity and measured data with ibaPDA-V6
- Connecting up to 64 HMI stations per ibaPDA-V6 system
- Local or centralized storage of video data
- Easy configuration with ibaPDA-V6 I/O manager
- Screen region and recording rate (frames per second) configurable
- Capture of mouse position and mouse key strokes
- Synchronized replay and analysis of video recordings and measured data in ibaAnalyzer
|
| | - Reliable Identification of Coils
- Areas of application
›› Detection of coil mix-ups ›› Determination of strip cuts (head/tail)
|
| | - Offline tool for generating rolling mill schedules on reversing stands
- Uses the current process data, no modelling
- Does not depend on materials, can be employed flexibly
- Can be integrated in the existing infrastructure, no transfer of know how to third parties
- Complete documentation
- Easy to use
|
| | - Parallel A/D converter for digital signals
- 40 digital, galvanically isolated input channels with sampling rates of 1 kHz up to 25 kHz per channel and signal level up to DC ±48 V
- Application in fault reporting systems for high-precision signal recording and subsequent evaluation by means of ibaAnalyzer
- Application with ibaPDA-V6, ibaLogic and ibaScope
- Data transfer with fiber optic cable technology; resistant against electromagnetic irradiation and suitable for longer distances
- Serial connection mode and ring topologies with external synchronization are possible
- With ibaPDA-V6 max. 5,120 signals per system in 1 ms
- When using ibaLogic in the multiplexed mode up to 96 devices can be cascaded within one fiber optic ring with up to 3,840 monitored signals per ring
|
| | Online monitoring of cyclical processes for quality assurance and machine diagnosis
|
| | - Provides multiple licenses by means of one dongle
- Manages licenses from distributed applications centrally
- License management for the following applications:
-ibaAnalyzer-DB - ibaAnalyzer-E-Dat - ibaAnalyzer-DAT-Extraktor - ibaDatManager - Reserves licenses for important applications
- Display of free and currently used licenses
- Event log
- Graphical statistics overview of the license use
|
| | - Integrated connection to iba measuring systems in OEM solutions
- Fast 8/16 bit Dual Port RAM data interface
- Bidirectional fiber optic link for analog and digital inputs and outputs
- Supported ibaNet protocols: 32Mbit, 32Mbit Flex
- Flexible setting of data rate, data size and formatting with 32Mbit Flex
- Different operation modes (cascading, point-to-point)
- Compact design
|
| | - Connection of VME based PLC systems to ibaPDA-V6 or ibaLogic
- Backwards compatible to ibaLink-SM-128V-i-2o
- Can be used in all common VME32 and VME64 systems
- Bidirectional fiber optic link for analog and digital inputs and outputs
- Unidirectional fiber optic link for analog and digital outputs or diagnosis
- Supported ibaNet protocols: 3Mbit, 32Mbit and 32Mbit Flex
- Flexible setting of data rate, data size and formatting with 32Mbit Flex
- Different operation modes (cascading, peer-to-peermode)
- Power supply via VMEbus
- Fast data transfer due to Dual Port RAM technology
- Block consistent mode
|
| | Inventory manager for iba software
|
| | Expansion of the I/O spectrum with I/O modules of the 750 series from WAGO/Beckhoff
|
| | - ibaPADU devices for fast data acquisition with sampling rate up to 25 kHz (40 μs)
- 8 analog and 8 digital inputs
- Digital inputs for 18 V to 32 V, sampling synchronized with analog inputs
- Robust housing, easy mounting
ibaPADU-8-ICP - 8 analog inputs with integrated ICP-interface for direct connection to ICP-sensors
- IMI ICP definition-compliant
- Detection of broken sensor or short-circuit on sensor
- Each analog input channel is equipped with a programmable amplifier and low-pass filter for optimization of signal dynamics
ibaPADU-8-M - 8 galvanically isolated analog inputs for ±10 V
|
| | - Parallel A/D converter with 8 analog and 8 digital output channels
- Every channel is galvanically isolated and has its own A/D converter with electrical isolation of 1.5 kV
- Acquisition cycle is 1 ms with a transmission of 64 analog and 64 digital signals per cycle.
- Up to 8 devices can be cascaded using fiber optic cables at the maximum distance of 6.561 feet between 2 devices
- RJ11-jack to connect a notebook using ibaCom-PCMCIA-F card
- Robust metal housing, assembly on the mounting rail
|
| | - Network independent battery powered data logger with integrated lithium ion battery
- 8 analog inputs, 16 bit resolution
- 8 digital inputs
- Synchronous data recording of all channels
- Creation of binary files in iba format or csv files
- Sampling rate from 1 sample/min. to 1000 samples/s
- External trigger
- Integrated 4 or 32 GB data storage
- USB interface
- Battery run-time up to 24 h during normal operation
- Rugged design, easy mounting
|
| | - Interface for acquiring data of Ametek LSP infrared line scanners
- Connection via standard Ethernet connection
- Supports binary and ASCII communication
- Acquires up to 1000 samples per line
- Color graded display of the temperature distribution in ibaAnalyzer or online in ibaQPanel
|
| | - Record measured values on machine tools
- ibaPDA
Xplorer interface for accessing SINUMERIK CNC control systems - Areas of application
›› Online monitoring and visualization ›› Make the machine IoT-capable ›› Benchmarking ›› Commissioning support ›› Calculate characteristics
|
| | - Data acquisition of the newest generation - new features and functions in ibaPDA-V7
|
| | |
| | |