ACCON-NetLink-USB compact

ACCON-NetLink-USB compact
The compact communication and programming adaptor between PC and S7 controllers.
Tillverkare: DELTA LOGIC
Artikelnr: 161701-USB

Product information "ACCON-NetLink-USB compact"

Small but nice

ACCON-NetLink-USB compact is the compact communication and programming adaptor between PC and S7 controllers. The electronics of the ACCON-NetLink-USB compact is placed in the box of a PROFIBUS connector what makes the adaptor very small and handy.
As all-rounder, the ACCON-NetLink-USB compact can be connected to the PLC via MPI, PROFIBUS and PPI. The ACCON-NetLink-USB compact independently detects the current bus settings of the PLC.

Perfect fields of application

As programming adaptor to create and change the PLC program
As communication adaptor for accessing the PLC's data

Varied ranges of application

Programming S7 controllers with STEP 7
Projecting HMI devices with WinCC flexible

Convincing and varied

  • The communication of the ACCON-NetLink-USB compact to the PC is effected via USB. It is fed by the PC via its USB connector.
  • The ACCON-NetLink-USB compact supports the parameterization of DP slaves via DP-V1 (class 2).
  • A driver for SIMATIC applications (ACCON-S7-NET) is included in delivery.

Technical highlights

  • Automatic bus profile detection
  • Voltage supply via USB
  • PROFIBUS connector with PG bushing

Technical Details

Supported operating systemsNo limitations (the driver for SIMATIC ACCON-S7-NET is only for Windows XP, 2003R2, 7, 2008R2, 8.1, 2012R2, 10)
Hardware requirementsUSB interface
Supported PLCsS7-200, S7-300, S7-400
Weight in kgCa. 0.18
Dimensions (W x H x D) in mm64 x 40 x 17
Protection typeIP 20
Supply voltage5 VDC via USB
External voltage feed possibleNo
Power consumption200 mA at 5 VDC via USB
Galvanically isolatedYes
Operating temperature0 °C to 60 °C
Allowed relative humidityOperation 5 % to 85 % at 30 °C (no bedewing), storage 5 % to 93 % at 40 °C (no bedewing)
Connection cable to the PLC9-pin SUB-D plug with PG bushing and terminating resistor
Connection cable to the PCUSB cable (3 m), stationary mounted, with USB connector type A
Supported bus systemsPROFIBUS, MPI, PPI
Supported bus profilesMPI and PROFIBUS (DP, Standard, Universal (DP/FMS), User-Defined) both fixed and even with automatic detection of the bus parameter, PPI
Supported transmission rates of the bus connection to the PLC9.6 Kbps up to 12 Mbps with automatic detection
Suaorted transmission rates USB12 Mbps (USB 1.1) and 480 Mbps (USB 2.0)
Max. number of connections to MPI, PROFIBUS, PPI32
Supported softwareACCON-AGLink, ACCON-S7-EasyLog, DELTALOGIC S7/S5-OPC-Server, ACCON-S7-Backup, ACCON-NCK-Explorer.
With the driver for SIMATIC ACCON-S7-NET you can additionally use SIMATIC Manager from V5.3, WinCC 6.0, WinCC flexible, ProTool, STEP 7-Micro/WIN, TIA Portal